e-STUDIO281c/351c/451c
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 48
305
Scanner
Image location adjustment
of secondary scanning
direction
(scanner section)
ALL
124
<92-164>
SYS
When the value
increases by “1”, the
image shifts by approx.
0.137 mm toward the
trailing edge of the
paper.
1
306
Scanner
Image location adjustment
of secondary scanning
direction
(scanner section)
ALL
113
<0-255>
SYS
When the value
increases by “1”, the
image shifts by approx.
0.0423 mm toward the
front side of the paper.
1
308
Scanner
Distortion mode
ALL
-
-
Moves carriages to the
adjusting position.
(Chap. 3.4.4)
6
330-0
Image
control
Image quality
closed-loop
control con-
trast voltage
correction/
Mode 2 maxi-
mum number
of time cor-
rected
Y
ALL
3
<0-255>
M
Sets the maximum cor-
rection number of time
of the contrast voltage
in the closed-loop con-
trol mode 2.
4
330-1
M
ALL
3
<0-255>
M
4
330-2
C
ALL
3
<0-255>
M
4
330-3
K
ALL
3
<0-255>
M
4
331-0
Image
control
Image quality
closed-loop
control laser
power correc-
tion/Mode 2
maximum
number of
time corrected
Y
ALL
2
<0-255>
M
Sets the maximum cor-
rection number of time
of the laser power in the
closed-loop control
mode 2.
4
331-1
M
ALL
2
<0-255>
M
4
331-2
C
ALL
2
<0-255>
M
4
331-3
K
ALL
2
<0-255>
M
4
332-0
Image
control
Image quality
closed-loop
control con-
trast voltage
correction/
Mode 1 maxi-
mum number
of time cor-
rected
Y
ALL
1
<0-255>
M
Sets the maximum cor-
rection number of time
of the contrast voltage
in the closed-loop con-
trol mode 1.
4
332-1
M
ALL
1
<0-255>
M
4
332-2
C
ALL
1
<0-255>
M
4
332-3
K
ALL
1
<0-255>
M
4
333-0
Image
control
Image quality
closed-loop
control laser
power correc-
tion/Mode 1
maximum
number of
time corrected
Y
ALL
1
<0-255>
M
Sets the maximum cor-
rection number of time
of the laser power in the
closed-loop control
mode 1.
4
333-1
M
ALL
1
<0-255>
M
4
333-2
C
ALL
1
<0-255>
M
4
333-3
K
ALL
1
<0-255>
M
4
334
Image
control
Main charger grid calibra-
tion voltage 1 (low)
ALL
300
<210-
390>
M
Transformer output cali-
bration of the main
charger grid bias. When
replacing the high-volt-
age transformer, the
values listed in attached
data sheet are entered.
(Unit: V)
1
335
Image
control
Main charger grid calibra-
tion voltage 2 (high)
ALL
1000
<900-
1100>
M
1
Adjustment mode (05)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
06/08