PREVENTIVE MAINTENANCE (PM)
4 - 25
4
Note:
Note:
When you clean the reference plate, never touch it directly with the cleaning brush etc. as the
surface of the reference plate is fragile.
Fig. 4-21
* j4.
Polarity adjustment plate
Apply two-rice-grain-amount of FLOIL (GE-334C) to the polarity adjustment plate (feeding
terminal).
Fig. 4-22
* j5.
Color toner cartridge sensor
Perform the cleaning of the surface of the color toner cartridge sensor when you replace
the color developer unit (e-STUDIO281c: 24,000 sheets / e-STUDIO351c: 30,000 sheets /
e-STUDIO451c: 37,500 sheets).
* k1.
Transfer belt drive roller -1, -2
Fully clean up the toner and such adhered to the roller with alcohol since an image failure
may occur if there are any bolts remaining on the roller.