e-STUDIO281c/351c/451c
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 8
2.1.2
Service call
Error code
Classification
Contents
Troubleshooting
C010
Drive system related
service call
Main motor abnormality: The main motor is not
rotating normally.
P. 5-52
C020
Developer motor abnormality: The developer motor
is not rotating normally.
P. 5-52
C030
Transport motor abnormality: The transport motor is
not rotating normally.
P. 5-52
C040
Paper feeding system
related service call
PFP motor abnormality: The PFP motor is not rotat-
ing normally. (the case that paper can be fed from
any drawer except the PFP)
P. 5-53
C130
Upper drawer tray abnormality: The upper drawer
tray-up motor is not rotating or the upper drawer
tray is not moving normally. (the case that paper
can be fed from any drawer except the upper
drawer)
P. 5-54
C140
Lower drawer tray abnormality: The lower drawer
tray-up motor is not rotating or the lower drawer tray
is not moving normally. (the case that paper can be
fed from any drawer except the lower drawer)
P. 5-54
C150
PFP upper drawer tray abnormality: The PFP upper
drawer tray-up motor is not rotating or the PFP
upper drawer tray is not moving normally. (the case
that paper can be fed from any drawer except the
PFP upper drawer)
P. 5-55
C160
PFP lower drawer tray abnormality: The PFP lower
drawer tray-up motor is not rotating or the PFP
lower drawer tray is not moving normally. (the case
that paper can be fed from any drawer except the
PFP lower drawer)
P. 5-55
C180
LCF tray-up motor abnormality: The LCF tray-up
motor is not rotating or the LCF tray is not moving
normally. (the case that paper can be fed from any
drawer except the LCF)
P. 5-56
C1A0
LCF end fence motor abnormality: The LCF end
fence motor is not rotating or the LCF end fence is
not moving normally. (the case that paper can be
fed from any drawer except the LCF)
P. 5-57
C1B0
LCF transport motor abnormality: The LCF trans-
port motor is not rotating normally. (the case that
paper can be fed from any drawer except the LCF)
P. 5-58
C260
Scanning system
related service call
Peak detection error: Lighting of the exposure lamp
(white reference) is not detected when power is
turned ON.
P. 5-59
C270
Carriage home position sensor not turning OFF
within a specified period of time: The carriage does
not shift from its home position in a specified time.
P. 5-59
C280
Carriage home position sensor not turning ON
within a specified period of time: The carriage does
not reach to its home position in a specified period
of time.
P. 5-59
C360
Copy process related
service call
Charger cleaner motor abnormality: Charger
cleaner motor is not rotating or wire cleaner is not
moving normally.
P. 5-90