e-STUDIO281c/351c/451c
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 142
859-0
Develop-
ment
Toner empty
detection
Y
ALL
(color)
0
<0-1>
M
Becomes “1” when
detecting the toner
empty.
0: Normal
1: Empty detected
14
859-1
M
ALL
(color)
0
<0-1>
M
14
859-2
C
ALL
(color)
0
<0-1>
M
14
860-0
Develop-
ment
Color auto-
toner sensor/
proper range
setting of OFF
level voltage
Upper limit
ALL
(color)
20
<0-1023>
M
Sets the range for judg-
ing whether the sensor
output value when the
sensor light source is
OFF is correct
or not.
4
860-1
Lower limit
ALL
(color)
0
<0-1023>
M
4
861-0
Develop-
ment
Color auto-
toner sensor/
proper range
setting of
standard light
amount volt-
age
Upper limit
ALL
(color)
205
<0-255>
M
Sets the range for judg-
ing whether the adjust-
ment result of sensor
light amount is correct
or not.
4
861-1
Lower limit
ALL
(color)
40
<0-255>
M
4
862-0
Develop-
ment
Color auto-
toner sensor/
proper range
setting of ref-
erence plate
output
Upper limit
ALL
(color)
950
<0-1023>
M
Sets the range for judg-
ing whether the sensor
output value for the ref-
erence plate is correct
or not.
4
862-1
Lower limit
ALL
(color)
205
<0-1023>
M
4
863-0
Develop-
ment
Color auto-
toner sensor/
proper range
setting of
developer out-
put
Upper limit
ALL
(color)
450
<0-1023>
M
Sets the range for judg-
ing whether the sensor
output value for the
sleeve is correct or not.
4
863-1
Lower limit
ALL
(color)
155
<0-1023>
M
4
864
Develop-
ment
Color auto-toner sensor/
sensor OFF output value
display at power ON
ALL
(color)
-
<0-1023>
M
Displays the sensor
output value when the
sensor light source is
OFF at power ON.
2
865
Develop-
ment
Color auto-toner sensor/
reference plate output
value display at power ON
ALL
(color)
-
<0-1023>
M
Displays the sensor
output value with the
standard light amount
for the reference plate
at power ON.
2
866-0
Develop-
ment
Color auto-
toner sensor/
abnormal
detection
potential dif-
ference set-
ting of
reference
plate output
Upper limit
ALL
(color)
820
<0-1023>
M
Sets the range for judg-
ing whether the differ-
ence between the
sensor output when the
sensor light source is
OFF and the sensor
output for the reference
plate is correct or not.
4
866-1
Develop-
ment
Lower limit
ALL
(color)
205
<0-1023>
M
4
867
Develop-
ment
Color auto-toner control
environment and life light
amount correction setting
ALL
(color)
0
<0-1>
M
Sets whether the sen-
sor light amount is cor-
rected or not depending
on the environment and
life.
0: Correction
1: No correction
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Pro-
cedur
e
Summary of Contents for e-studio281c