e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
BACKUP FUNCTION
12 - 2
12.1.3
Backup files
The following files are saved in the root directory of the USB device by backing up.
12.1.4
Cloning procedure
[A] Backup procedure
(1)
Shut down the equipment.
(2)
Connect the USB device [1] to the USB port [2] on the right upper cover.
Fig.12-1
(3)
When "SRAM Clear Mode" appears on the LCD, key in [0] to select "0. Set Serial Number" and
then press the [START] button.
(4)
Key in the serial number on the label attached to the rear cover of the equipment, and then press
the [OK] button.
(5)
"Serial Number Setting completed" is displayed.
(6)
Turn the power OFF.
(7)
Press the HS-59 - [Backup SRAM Data to USB].
(8)
Enter a password (max. 15 characters) set for the backup data.
(9)
"Backup Successfully done Restore the MFP" is displayed on the LCD screen when the backup
has been properly completed.
(10) Shut down the equipment.
Filename
Remark
Modelname_MFPSerialNo_yyyy-MM-dd_hh-mm
E.g.: When backup was performed at 13:59 on
October 1st, 2010.
Txxx_CUK911379_2010-10-01_13-59
[2]