e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
REPLACEMENT OF PC BOARDS/HDD
9 - 1
9.
REPLACEMENT OF PC BOARDS/HDD
9.1
Removal and Installation of PC Boards/HDD
Notes:
When the PC board/HDD is replaced, refer to the respective Notes and Cautions of
“Replacement of PC boards and HDD” in
P. 9-11 "9.2 Precautions and Procedures for
Replacing PC Boards and HDD/SSD".
9.1.1
SYS Board cover
9.1.2
SYS board
Notes:
•
When the SYS board or main memory has been replaced, be sure to perform the calibration
of memory.
•
When performing the calibration of memory, press the [ENERGY SAVER] button and turn the
power ON.
•
When the equipment is started up normally, the calibration has been completed.
•
If the calibration is not performed, the equipment may be not started up normally.
(1)
Remove the rear cover.
(2)
Remove 2 screws and take off the SYS
board cover [1] by sliding it toward the right
side.
Fig. 9-1
(1)
Remove the SYS Board cover.
P. 9-1 "9.1.1 SYS Board cover"
(2)
Remove the HDD unit.
P. 9-4 "9.1.3 Hard disk (HDD)"
(3)
Remove the SYS board cooling fan.
P. 4-100 "4.7.15 SYS/HDD cooling fan
(4)
Remove 1 screw [1] from the harness guide
of SYS board.
(5)
Release the lock by tilting the flap [2] and
remove the flat cable [3].
Fig. 9-2