e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 180
[F350] SLG board abnormality (e-STUDIO206L/256/306/356/456/506)
[F400] SYS/HDD cooling fan abnormality
Replacement part
Remark
SRAM on the SYS board
Classification
Contents
Circuit related service call
SLG board abnormality
Check Item
Measure
SLG board
Board check
Combination of the firmware
version
•
Check the combination of the firmware version of the system
ROM, engine ROM, and scanner ROM.
•
Reinstall the scanner ROM firmware.
Replacement part
Remark
SLG board
Classification
Contents
Circuit related service call
SYS/HDD cooling fan abnormality
Check Item
Measure
SYS/HDD cooling fan
Check if the fan is rotating properly. If not, check if any foreign
object is adhered.
SYS board
Check the connector (*1) and relay connector.
*1: CN112: e-STUDIO206L/256/306/356/456/506
CN105: e-STUDIO207L/257/307/357/457/507
Replacement part
Remark
SYS board
SYS/HDD cooling fan