e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 84
8.3.4
Paper misfeeding
[E110] ADU misfeeding
Classification
Error content
Paper misfeeding
Jam not reaching the registration sensor)
Proce
dure
Check item
Result
Measure
Next
Step
1
Open the ADU. Is there
any paper in front of the
registration sensor?
Yes
Remove the paper.
No
2
2
Is the registration sensor
working?
(Perform the input check
in the test mode: 03-
[FAX]ON/[9]/[A])
Yes
3
No
•
Check if the connector of the 1st transport
sensor is disconnected.
•
Check if the connector CN316 on the LGC
board is disconnected.
•
Check if the connector pins are
disconnected and the harnesses are open
circuited.
•
Check if the conductor pattern on the LGC
board is short circuited or open circuited.
•
Replace the 1st registration sensor.
•
Replace the LGC board.
3
Is the ADU clutch
working? (Perform the
output check in the test
mode: 03-222)
Yes
4
No
•
Check if the connector of the ADU clutch is
disconnected.
•
Check if the connector CN304 on the LGC
board is disconnected.
•
Check if the connector pins are
disconnected and the harnesses are open
circuited.
•
Check if the conductor pattern on the LGC
board is short circuited or open circuited.
•
Replace the ADU clutch.
•
Replace the LGC board.
4
Rollers in the ADU
•
Check the rollers in the ADU. Replace them
if they are worn out.
Parts to be replaced
Remark
ADU clutch
LGC board
Rollers in the ADU