SETTING / ADJUSTMENT
6 - 10
[C] Reproduction ratio of secondary scanning direction (Fine adjustment of main motor
rotation speed (Copier/Printer))
<Procedure>
(1)
Performs FS-05.
(05 Adjustment Mode)
(2)
Press [1]
[TEST PRINT]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from
the lower drawer (Refer to *).
(3)
Check the grid pattern on the test chart printed out and measure the distance C from the 10th
line at the leading edge of the paper to the 30th line of the grid pattern.
*
Normally, the 1st line of the grid pattern is not printed.
(4)
Check if the distance C is within 200±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance C again.
FS-05
Key in code [4526]
[START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory)
“100% A” is displayed
Press [1]
[TEST PRINT]
(A grid pattern is printed out.)
*
The larger the adjustment value is, the longer the distance C becomes (approx. 0.25 mm/
step).