e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SELF-DIAGNOSTIC MODE
5 - 9
5.4
[03 TEST MODE]
5.4.1
Input check
The status of each input signal can be checked by operating the [F1], [F3] and the digital keys.
<Operation procedure>
Notes:
•
Initialization is performed before the equipment enters the test mode.
•
The PRINT DATA lamp blinks when the input check is running.
•
"100%" is displayed on the 03 test mode start screen. "C%" is displayed when [F1] is turned ON.
"S%" is displayed when [F2] is turned ON. "F%" is displayed when [F3] is turned ON.
Fig.5-7
Refer to the "Self-diagnostic code list" (separate document) for the items to be checked and the
condition of the equipment when [A] through [H] are highlighted.
[START]
[FAX]
or
[COPY]
[Digital keys]
[CLEAR]
(LCD ON)
[CLEAR]
Service Mode
Exit
[03]
[FS]