e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
© 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY AND REPLACEMENT
4 - 142
4.11.5
Exit motor (M10)
(1)
Remove the right rear cover.
P. 4-4 "4.1.10 Right rear cover"
(2)
Remove the paper exit unit.
P. 4-139 "4.11.2 Paper exit unit <35ppm/
(3)
Remove the connecting port cover.
P. 4-3 "4.1.7 Connecting port cover"
(4)
Remove 1 screw and take off the exit motor
assembly [1].
Fig. 4-380
(5)
Disconnect 1 connector from the exit motor
assembly [1].
Fig. 4-381
(6)
Remove the belt [2].
Fig. 4-382