6
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
SETTING / ADJUSTMENT
6 - 11
(3) [CANCEL]
[CANCEL]
[SETTINGS] (Return to code entry screen)
[1]
[SETTINGS]
Select the paper source
[START] (A grid pattern with 10 mm squares
is printed out.)
(4) Check the grid pattern on the test chart printed out and measure the distance B from the left edge
of the paper to the 6th line of the grid pattern.
(5) Check if the distance B is within 52±0.5 mm.
(6) If not, use the following procedure to change values and measure the distance B again.
(Adjustment Mode)
(Key in the code [4018])
[START]
(Key in the sub code)
[START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory).
Press [1]
[SETTINGS]
Select the paper source
[START]
(A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance B becomes (approx. 0.04 mm/
step).
[C] Reproduction ratio of secondary scanning direction (Fine adjustment of main motor
rotation speed (Copier/Printer))
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(Adjustment mode)
(2) [SETTINGS]
[USER FUNCTIONS]
Select [DRAWER]
Select [DRAWER1]
Set the paper size to A3/LD.
[OK]
Set A3/LD for the paper in upper drawer.
(3) [CANCEL]
[CANCEL]
[SETTINGS] (Return to code entry screen)
[1]
[SETTINGS]
[START] (A grid pattern with 10 mm squares is printed out.)
(4) Check the grid pattern on the test chart printed out and measure the distance C from the 10th
line at the tail end of the paper to the 30th line of the grid pattern.
* Normally, the 1st line of the grid pattern is not printed.
(5) Check if the distance C is within 200±0.5 mm.
(6) If not, use the following procedure to change values and measure the distance C again.
(Adjustment Mode)
(Key in code [4009])
[START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory)
Press [1]
Press [SETTINGS]
Select [DRAWER1]
[START]
(A grid pattern is printed
out.)
* The larger the adjustment value is, the longer the distance C becomes (approx. 0.14 mm/
step).