e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY AND REPLACEMENT
4 - 100
4.9.3
Fuser unit cover/Fuser unit guide
(1) Take off the fuser unit.
(2) Place the fuser unit upside down.
Remove 1 screw and release the latch, take
off the bias plate [1].
Fig. 4-264
(3) Remove 2 screws and then take off entrance
guide [2].
Notes:
1. When removing the entrance guide, be
careful not to scratch the fuser roller and
pressure roller with the entrance guide
edge.
Fig. 4-265
2. When installing the entrance guide, make
sure that the part of the entrance guide
shown in the figure is outside the fuser
unit cover.
Fig. 4-266
[1]
[2]