4
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
DISASSEMBLY AND REPLACEMENT
4 - 39
4.6.7
Bypass separation pad <20L/23L/25L/20H/23H/25H>
4.6.8
Bypass paper sensor (S6)
(1) Take off the right cover.
(2) Take off the Lower bypass feed guide.
P. 4-36 "4.6.4 Lower bypass feed guide"
(3) Remove the bypass separation pad [1].
Fig. 4-98
(1) Take off the bypass feed roller.
P. 4-36 "4.6.5 Bypass feed roller <20L/
P. 4-37 "4.6.6 Bypass feed roller <23LA/
(2) Release 3 latches, take off the bypass paper
sensor [1], and disconnect the connector.
Fig. 4-99
[1]
[1]