6
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
SETTING ADJUSTMENT
6 - 83
6.7
Paper Feeding System
Adjust the position of the sensor in the code 05-9092 within the adjustment values from 460+/-100.
6.7.1
Adjustment of the media sensor position
<Procedure>
• Remove 1 screw and take off the SFB lower cover.
Fig.6-30
• Turn the power of this equipment ON while pressing [0] and [5] simultaneously. Then perform the
code 9092.
Turn a screw to make the displayed adjustment value fall within the range from 460+/-100.
The value increases to approx. 160 by turning the screw 360 degrees clockwise.
Fig.6-31
SFB lower cover
Screw