4
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT
4 - 175
4.9.5
Entrance guide cover
4.9.6
Separation finger
(1) Take off the fuser unit.
(2) Take off the pressure roller cover.
P. 4-173"4.9.2 Pressure roller cover"
(3) Remove 2 screws and take off the entrance
guide cover [1].
Notes:
In order to prevent abrasion powder from
dirtying the bed surface, operate after laying
a sheet on the bed surface. In addition, clean
the dirt off receiving dish [2].
Fig. 4-502
Notes:
Fix the screw in the position as shown in the
figure unless paper jams occur at the
entrance of the fuser unit.
Fig. 4-503
(1) Take off the transport guide-1.
P. 4-174"4.9.3 Transport guide-1"
(2) Remove 2 screws, take off the separation
finger unit [1] and cover plate [2].
Fig. 4-504
[ 1 ]
[ 2 ]
[ 1 ]
[ 2 ]