e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY and REPLACEMENT
4 - 34
4.3.16
Carriage home position sensor (S6)
4.3.17
Platen sensor (S7)
4.3.18
SLG board (SLG)
(1) Take off the top rear cover.
(2) Remove the seal.
(3) Disconnect 1 connector. Release the latches
and take off the carriage home position
sensor.
Fig. 4-93
(1) Remove the RADF.
(2) Take off the top rear cover.
(3) Disconnect 1 connector. Release the latches
and take off the platen sensor.
Fig. 4-94
(1) Open the RADF.
(2) Take off the lens cover.
(3) Disconnect 10 connectors, remove 4 screws
and take off the SLG board.
Fig. 4-95
Carriage
home position sensor
Platen sensor
SLG board