e-STUDIO2555C/3055C/3555C/4555C/5055C
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 108
[ED10] Skew adjustment motor (M1) home position detection abnormality
MJ-1107/1108 (when MJ-6104 is installed)
Check item
Measures
Finisher
Check if the connector on the equipment is disconnected from the
finisher or the harnesses are open circuited. Correct if any.
Parts to be replaced
Remark
PFC board
LGC board
Classification
Error content
Other paper jam
Skew adjustment motor (M1) home position detection abnormality
Check item
Measures
Skew adjustment motor (M1)
Rotate skew adjustment motor and fix its mechanism if it does not
rotate smoothly.
Skew HP sensor (S2)
Skew adjustment motor (M1)
Hole punch control PC board
Check if the connectors on the hole punch controller PC board (HP
board) are disconnected from the skew HP sensor (S2) and the
skew adjustment motor, or the harnesses are open circuited.
Correct if any.
Parts to be replaced
Remark
Skew adjustment motor
Skew HP sensor
Hole punch control PC board