Service call
Error code
Classification
Contents
Troubleshooting
C020
Drive system related
service call
Developer drive motor abnormality: The
developer drive motor is not rotating normally.
C040
Paper feeding
system related
service call
PFP motor abnormality: The PFP motor is not
rotating normally. (the case that paper can be
fed from any drawer except the PFP)
C130
1st drawer tray abnormality: The tray-up motor
is not rotating or the 1st drawer tray is not
moving normally. (the case that paper can be
fed from any drawer except the 1st drawer)
C140
2nd drawer tray abnormality: The tray-up
motor is not rotating or the 2nd drawer tray is
not moving normally. (the case that paper can
be fed from any drawer except the 2nd
drawer)
C150
PFP upper drawer tray abnormality: The PFP
upper drawer tray-up motor is not rotating or
the PFP upper drawer tray is not moving
normally. (the case that paper can be fed from
any drawer except the PFP upper drawer)
C160
PFP lower drawer tray abnormality: The PFP
lower drawer tray-up motor is not rotating or
the PFP lower drawer tray is not moving
normally. (the case that paper can be fed from
any drawer except the PFP lower drawer)
C180
LCF tray-up motor abnormality: The LCF tray-
up motor is not rotating or the LCF tray is not
moving normally. (the case that paper can be
fed from any drawer except the LCF)
C1A0
LCF end fence motor abnormality: The LCF
end fence motor is not rotating or the LCF end
fence is not moving normally. (the case that
paper can be fed from any drawer except the
LCF)
C1B0
LCF transport motor abnormality: The LCF
transport motor is not rotating normally (when
paper can be fed from any drawer except the
LCF).
C260
Scanning system
related service call
Peak detection error: Lighting of the exposure
lamp (white reference) is not detected when
power is turned ON, or communication error
with CCD board.
C270
Carriage home position sensor not turning
OFF within a specified period of time: The
carriage does not shift from its home position
in a specified time.
C280
Carriage home position sensor not going ON
within a specified time
C290
Scanner fuse blowout: 24V power for the
scanning system is not supplied at the
scanner warming-up after power-ON.