12.3.4
Precautions
•
In the High Security Mode, an integrity check system is operated at every restart. If F521 (integrity
check error) is displayed, take the necessary measures following the troubleshooting procedure.
•
When a self-diagnostic mode is started in the High Security Mode, an authentication screen
appears. Enter the default user name and password as follows:
Default user name: service
Default password: #1048#
•
If a password change screen appears, reset the password according to the rules below.
- It must not include the user name.
- It must be a combination of letters of the alphabet and numbers.
- It must be 6 characters or more. (Maximum 64 characters)
- The same character must not be repeated 4 times within the new password.
- The old and the new passwords must not be the same.
•
In the High Security Mode, restrictions are set to the following self-diagnostic codes:
•
In the above case, the password is not reset. The password setting can be changed with the code
08-8919.
•
The HDD is initialized (and the saved user data are deleted) when the equipment returns to the
normal mode from the High Security Mode. Be sure to back up user data before having it do so.
•
After the equipment enters the High Security Mode, ask the administrator for the equipment to select
[FULL] and perform the Integrity check manually.
Code
Contents
08-8910
The setting value is changed to “2”. “0” is not settable.
08-8911
The setting value is changed to “3”.
08-8924
The setting value is changed to “1”. Values other than “1” are not settable.
08-9110
“0” is not settable.
08-9193
If “0” is set for the value, the setting will not comply with IEEE2600.1 Security Standards
Requirement.
08-9379
The setting value is changed to “1”.
08-9819
The setting value is changed to “1”. If “0” is set for the value, the setting will not comply
with IEEE2600.1 Security Standards Requirement.