e-STUDIO555/655/755/855
© 2009 - 2011 TOSHIBA TEC CORPORATION All rights reserved
POWER SUPPLY UNIT
16 - 6
16.4 Fuse
When the power supply secondary fuse is blown out, confirm that there is no abnormality with each part
using the following table.
Voltage
Board/unit
Part
Fuse type
+24VD1
LGC board Web motor
M4
F4: 8A (Semi time-lag)
New toner supply motor
M5
New toner transport motor
M6
Hopper motor
M7
Recycle toner transport motor
M8
Used toner transport motor
M9
Wire cleaner drive motor
M12
Cleaning brush drive motor
M13
Transfer belt cam motor
M15
Transport motor
M17
Exit motor
M18
Reverse motor
M19
Auto-toner sensor
S12
Drum surface potential sensor
S13
Main switch
SW6
High-voltage transformer
HVT
Discharge LED
ERS
+24VD1
LGC board Registration motor
M16
F4: 8A (Semi time-lag)
Tray-up motor-1
M21
Tray-up motor-2
M22
Reverse section cooling fan-1
M24
Reverse section cooling fan-2
M25
IH board cooling fan
M26
Duct out fan
M27
Exit section cooling fan
M29
Tandem LCF tray-up motor
M41
Tandem LCF end fence motor
M42
Horizontal transport section driving clutch-1 CLT1
Horizontal transport section driving clutch-2 CLT2
Horizontal transport section driving clutch-3 CLT3
Bypass feed clutch
CLT4
1st drawer transport clutch
CLT5
1st drawer feed clutch
CLT6
2nd drawer transport clutch
CLT7
2nd drawer feed clutch
CLT8
3rd drawer transport clutch
CLT9
3rd drawer feed clutch
CLT10
4th drawer transport clutch
CLT11
4th drawer feed clutch
CLT12
Gate solenoid
SOL2
Bypass pickup solenoid
SOL3
Tandem LCF pickup solenoid
SOL7
Tandem LCF end fence solenoid
SOL8
External LCF
+24VD2
LGC board Developer unit motor
M10
F5: 8A (Semi time-lag)
Fuser cooling fan
M28
Duct in fan
M30
Developer unit fan
M31
Laser unit cooling fan
M32
Switching regulator cooling fan-1
M34
Switching regulator cooling fan-2
M35
Drum separation finger solenoid
SOL1
Copy key card