13
© 2009 - 2011 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO555/655/755/855
FUSER UNIT
13 - 15
13.6 Disassembly and Replacement
Notes:
When assembling or disassembling the fuser unit, be careful of the following items to avoid the
harnesses catching or other problems:
1. When installing the stay, be sure not to catch the harness on the screw or the driver.
2. Be sure that the harness is fixed with the clamp and it is not protruding out of the stay.
3. Connect the drawer connector securely.
4. Be sure that the harness of the web detection sensor is arranged within the stay as shown in
the figure, and that it is not sagging.
5. Be sure that you arrange the harness of the pressure roller thermistor while bypassing the
shaft as shown in the figure.
6. Be sure that the harness of the web motor runs through the harness clamp.
7. When installing the fuser unit front cover, be sure not to catch the connector of the web motor.
Fig. 13-10
(1)
Harness
Screw
Stay
(2)
Harness clamp
Harness clamp
(3)
Connector
(4)
Harness
Web detection sensor
Shaft
Harness
Harness clamp
(5)
Web motor
Harness clamp
Connector
(6)
Fuser unit front cover
Connector
(7)