BACnet Setup
https://www.toshiba.com/tic/
71
Table 8.
BACnet
®
Analog Values.
Analog Value
Object ID
Object Name
Description
Value
Access
Analog
Value #0
(AV0)
Output Speed
Output speed (output frequency / base
frequency
x motor nameplate rpm, ie. 30 / 60 x
1770 = 885)
RPM
R
Analog
Value #1
(AV1)
Output Freq
Frequency output
Hz
R
Analog
Value #2
(AV2)
DC Bus Volt
DC bus voltage
V
R
Analog
Value #3
(AV3)
Output Volt
Voltage output to the motor
V
R
Analog
Value #4
(AV4)
Output Current
Current generated by the motor
A
R
Analog
Value #5
(AV5)
Output Torque
Torque generated by the motor
%
R
Analog
Value #6
(AV6)
Input Power
Power consumed by the drive
kW
R
Analog
Value #7
(AV7)
Output Power
Power consumed by the motor
kW
R
Analog
Value #8
(AV8)
Total Input
Power
Total cumulative power consumed by
the drive
kWh
R
Analog
Value #9
(AV9)
Total Output
Power
Total cumulative power consumed by
the motor
kWh
R
Analog
Value #10
(AV10)
PID Fbck
PID feedback value
Hz
R
Analog
Value #11
(AV11)
Run Time
Total time of operation
Hours
R
Summary of Contents for DN-68249-003
Page 1: ...ADJUSTABLE SPEED DRIVES Q9 DN 68249 003 INSTALLATION OPERATION MANUAL April 2020 ...
Page 2: ......
Page 3: ...Document Number 68249 003 April 2020 Q9 Plus ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...Table of Contents Q9 Plus ASD Install Op Manual iv https www toshiba com tic ...
Page 305: ......