11. DETACHMENTS
In a section, Detachments, the models are expressed as follows for convenience.
AP0
24
: MMD
-
AP0
246
HP
UL
to AP0
306
HP
UL
AP036 : MMD
-
AP0366HPUL to AP0546HPUL
No. Part name
Procedure
Remarks
①
②
1. Detachment
1) Remove the fixing screws A which fix the suction panel.
Loosen the fixing screws B.
2) Slide the suction panel to the arrow side and then
remove the panel.
2. Attachment
1) Hook the suction panel to the fixing screws B and
tighten screws.
2) Attach the removed screws A to the original positions.
AP0
24
type
Electric
parts
box cover
1. Detachment
1) Remove the screw A of the electric parts box cover to
loosen screw B.
2) As shown in the right figure, when sliding it toward
arrow direction and pulling to this side, the electric
parts cover opens using the hinge part as a shaft.
3) Take off the slit of the electric parts box cover from the
projection of the side plate and then remove the cover.
2. Attachment
1) Hook the slit of the electric parts box cover to the
projection of the side plate, close the cover, enter
screw B in the Key hole and then slide it.
2) Fix the electric parts box cover by tightening with
screws A and B.
Suction
panel
Fixing screw B
Fixing screw A
Fixing screw B
Fixing screw A
Suction
panel
Suction
panel
NOTE
WARNING
Be sure to stop operation of the air conditioner before
work and then turn off switch of the breaker.
CAUTION
Be sure to put on gloves during working time;
otherwise an injury will be caused by a part, etc.
AP036 type
Projection on the side plate
Slit
Side plate
Electric parts box cover
Hinge part
Screw B
Key hole
Screw-A
- 86 -