- 370 -
e
Bar code height calculation method
Example) In the following conditions:
203-dpi print head, Module width: 02, Recommended bar code height: 33x
(25.4 m / 203 dpi) x 2 dots x 33x
≈
8.25 m
Since the height is specified in units of 0.1 mm, “0082” or “0083” is to be set as 8.25 mm.
f
Max. number of data digits
Version of bar code
Max. number of digits
GS1 DataBar
13 digits (Numeral only)
GS1 DataBar Stacked
13 digits (Numeral only)
GS1 DataBar Stacked Omnidirectional
13 digits (Numeral only)
GS1 DataBar Limited
13 digits (Numeral only)
GS1 DataBar Expanded
74 digits (Numeral only) *1
41 digits (Alphabet only)
GS1 DataBar Expanded Stacked
74 digits (Numeral only) *1
41 digits (Alphabet only)
*1: Max. 74 digits/41 digits, including AI and FID.
In the following case, the print results vary in spite of the same number of digits.
Non
printable: “1A2B3C4D5E6F7G8H9I0J1K2L3M4N5O6P7Q8R9S0T1U2V3W”
Printable:
“ABCDEFGHIJKLMNOPQRSTUVW12345678901234567890123”
g
Check digit exclusively for each bar code version
Version of bar code
Check digit
GS1 DataBar
MOD79
GS1 DataBar Stacked
MODE79
GS1 DataBar Stacked Omnidirectional
MOD79
GS1 DataBar Limited
MOD89
GS1 DataBar Expanded
MOD211
GS1 DataBar Expanded Stacked
MOD211
For the check digit calculation method, refer to ISO 24724 or AIM ITS 99-001.
Summary of Contents for B-SX4T Series
Page 89: ... 85 F Price font 2 POP font G Price font 3 POP font H DUTCH801 Bold Times Roman Proportional ...
Page 325: ... 321 2 GB18030 code tables TBD ...
Page 326: ... 322 TBD ...
Page 327: ... 323 TBD ...
Page 328: ... 324 TBD ...
Page 329: ... 325 12 9 TrueType FONT 1 PC 850 2 PC 8 ...
Page 330: ... 326 3 PC 852 4 PC 857 ...
Page 331: ... 327 5 PC 851 6 PC 855 ...
Page 332: ... 328 7 PC 1250 8 PC 1251 ...
Page 333: ... 329 9 PC 1252 10 PC 1253 ...
Page 334: ... 330 11 PC 1254 12 PC 1257 ...