- 273 -
LCD Messages
Printer Status
Output Signal
of Upper Line (English)
Busy Select nFault
PError
EEPROM ERROR
An EEPROM for back-up cannot be
read/written properly.
H L L L
SYSTEM ERROR
(a) A command has been fetched from an
odd address.
(b) Word data has been accessed from a
place other than the boundary of the word
data.
(c) Long word data has been accessed from
a place other than the boundary of the
long word data.
(d) An undefined command in a place other
than the delay slot has been decoded.
(e) An undefined command in the delay slot
has been decoded.
(f) A command which rewrites the data in the
delay slot has been decoded.
H L L L
RFID WRITE ERROR
Writing data onto the RFID tag continuously
failed for the maximum number of RFID write
retries.
H L L L
RFID ERROR
The printer cannot communicate with the
RFID module.
H L L L
INPUT PASSWORD
The printer is waiting for a password to be
entered.
H L L L
PASSWORD INVALID
Password entered was not correct
consecutively for three times.
H L L L
RFID CONFIG ERR
B-SX704-RFID-U2-US-R only
RFID module’s destination code is not
specified
H L L L
9.3 E-MAIL
The printer can notify the PC of the printer status by e-mail. The status to be notified by e-mail is the
same as the status which is notified through the serial interface. For details, refer to the Network
Specification (TAA-1401).
Summary of Contents for B-SX4T Series
Page 89: ... 85 F Price font 2 POP font G Price font 3 POP font H DUTCH801 Bold Times Roman Proportional ...
Page 325: ... 321 2 GB18030 code tables TBD ...
Page 326: ... 322 TBD ...
Page 327: ... 323 TBD ...
Page 328: ... 324 TBD ...
Page 329: ... 325 12 9 TrueType FONT 1 PC 850 2 PC 8 ...
Page 330: ... 326 3 PC 852 4 PC 857 ...
Page 331: ... 327 5 PC 851 6 PC 855 ...
Page 332: ... 328 7 PC 1250 8 PC 1251 ...
Page 333: ... 329 9 PC 1252 10 PC 1253 ...
Page 334: ... 330 11 PC 1254 12 PC 1257 ...