- 17 -
g
nInit (Printer
←
Host)
z
Reset request signal from the host.
z
Normally at “High” level. A low on this input causes the printer to be initialized in the
same manner as when the power is turned on.
* When “Reset process when the nInit signal is ON” is set to “OFF” in the parameter setting
in the system mode, the printer is not initialized even if it receives a low signal.
z
When the nInit signal is input during printing, the printer completes printing one tag/label
which is being printed, cancels the next processing, then is initialized in the same manner
as when the power is turned on.
* When “Reset process when the nInit signal is ON” is set to “OFF” in the parameter setting
in the system mode, the next process proceeds without being canceled.
z
Minimum pulse width of 0.5 µsec.
h
Select (Printer
→
Host)
z
This is an output signal which indicates whether the printer is in Pause state or placed
online. The printer can receive data while placed online.
z
The signal is at “Low” level while the printer is in a Pause state.
z
The signal is kept at “Low” level (in a Pause state) until the current state (one of the
following states) is reset.
•
Pause state caused by the [PAUSE] key
•
Paper end state
•
Ribbon end state
•
Head open state
•
Printer error state
•
Initialization in progress upon power on or receipt of the nInit signal
i
nFault (Printer
→
Host)
z
Output signal indicating that the printer is in a Fault state.
z
At “Low” level while the printer is in a Fault state.
z
The signal is kept at “Low” level (in a Fault state) until the current state (one of the
following states) is reset.
•
Pause state caused by the [PAUSE] key
•
Paper end state
•
Ribbon end state
•
Head open state
•
Printer error state
•
Initialization in progress upon power on or receipt of the nInit signal
j
PError (Printer
→
Host)
z
Output signal indicating a label end or ribbon end state.
z
At “High” level when the printer is in a label end or ribbon end state.
z
Turns to “Low” level when the label end or ribbon end state is reset.
k
+5 V
z
This is not a signal but a +5 V power supply voltage.
z
The maximum current of 500 mA can be taken out.
l
nSelectIn (Printer
←
Host)
z
Not used
11
nAutoFd (Printer
←
Host)
z
Not used
Summary of Contents for B-SX4T Series
Page 89: ... 85 F Price font 2 POP font G Price font 3 POP font H DUTCH801 Bold Times Roman Proportional ...
Page 325: ... 321 2 GB18030 code tables TBD ...
Page 326: ... 322 TBD ...
Page 327: ... 323 TBD ...
Page 328: ... 324 TBD ...
Page 329: ... 325 12 9 TrueType FONT 1 PC 850 2 PC 8 ...
Page 330: ... 326 3 PC 852 4 PC 857 ...
Page 331: ... 327 5 PC 851 6 PC 855 ...
Page 332: ... 328 7 PC 1250 8 PC 1251 ...
Page 333: ... 329 9 PC 1252 10 PC 1253 ...
Page 334: ... 330 11 PC 1254 12 PC 1257 ...