15. MAJOR UNIT REPLACEMENT
EM18-33031
15.6 RIBBON MOTOR SENSORS (TAKE-UP, FEED)
15-11
15.6 RIBBON MOTOR SENSORS (TAKE-UP, FEED)
15.6.1 Ribbon Motor Sensor (Take-up)
1) Remove the side panel (L). (Refer to Section 3.2.)
2) Disconnect the sensor harness from the ribbon motor sensor ass’y (take-up).
NOTE: The other end of the sensor harness is connected to the Main PC board.
3) Remove the SMW-3x6 screw to detach the ribbon motor sensor ass’y (take-up).
4) Detach the ribbon motor sensor (take-up) from the ribbon sensor plate (take-up) in the following
steps.
NOTE: The ribbon motor sensor (take-up) is attached to the plate with the four hooks.
(1) Pull the ribbon motor sensor (take-up) in the direction indicated by the arrow to unhook the
two hooks on the connector side.
(2) Move the ribbon motor sensor (take-up) in the direction indicated by the arrow to unhook the
other hooks.
(3) Detach the ribbon motor sensor (take-up) from the plate.
Sensor Harness
SMW-3x6 Screw
Ribbon Motor Sensor Ass’y (Take-up)
Ribbon Sensor Plate (Take-up)
Ribbon Motor Sensor (Take-up)
Hook
(1)
(2)
(3)