5. SYSTEM MODE
EM18-33031
5.5 SET PARAMETERS
5-40
5.5.24 X ADJUST
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
+99.5 -99.5 0.1 Decimal Exist 2
1 None mm
NOTES
:
1. The X ADJUST parameter can fine adjust the print position in X-coordinate (horizontal direction). The fine
adjustment shall be performed so that the print position falls within the effective print width. (The X
coordinate fine adjustment in the negative (-) direction is effective until the print field reaches coordinate 0.
The coordinate does not change any further even if the fine adjustment is continued in the negative
direction.)
2. The X-coordinate fine adjustment value is not applied to self-diagnosis results printing (maintenance
counter and parameter settings, and auto diagnosis).
3. The X-coordinate fine adjustment value is the sum of the fine adjustment values set in the system mode
(by key operation) and set by command (from the PC). The max. value is ±99.5mm.
5.5.25 HEAT ENERGY TYPE
・
TRANS.(RIBBON)
・
DIRECT THERMAL
NOTES
:
1. The HEAT ENERGY TYPE parameter is intended to make the printer perform appropriate printing for
the supplies used (media such as label and tag, and ribbon). Use of a different supply from the setting
may cause poor printing. For details, refer to the Supply Specification for the B-EX6T1 series.
2. If “CN” is selected for the parameter clear destination, this parameter is not displayed on the menu.
Therefore, the initial value of this parameter cannot be changed. (The initial value is fixed. See Section
5.8.3 Parameter Clear.)
5.5.25.1 TRANS. (RIBBON)
・
SR1:AG2,AG4,AG6E
・
SR2:RG2,FG2,SG2
・
R1: AS1
・
R2: RS1
・
R3: (Resin3)
・
Generic
・
rsv1: (Reserved1)
・
rsv2: (Reserved2)
・
rsv3: (Reserved3)
・
rsv4: (Reserved4)
X Y Z
–
+