– 8 –
GENERAL ADJUSTMENTS
8. SELF DIAGNOSTIC FUNCTION
1) Press “9” button on Remote Control during display of adjustment menu in the service mode.
The diagnosis will begin to check if interface among IC’s are executed properly.
2) During diagnosis, the following displays are shown.
SELF CHECK
NO. 23 * * * * * *
POWER
: 000
BUS LINE : OK
BUS CONT : OK
BLOCK
: MAIN SUB
SET ID
: FF
EEP VER
: FF
OPT1 : 02
OPT2 : A4
DVI
NO 23009621
ERR CODE : 030000
���
���
���
���
���
���
���
���
���
Part number of microprocessor (QA01)
���
Operation number of protection circuit (current limiter) . . . . “000” is normal.
���
BUS line check
“OK” ................... Normal
“SCL-GND” or “NG” .......... SCL-GND short circuit
“SDA-GND” or “NG” .......... SDA-GND short circuit
“SCL-SDA” or “NG” ........... SCL-SDA short circuit
���
BUS line ACK (acknowledge) check
“OK” ..................... Normal
Display of Location Number . . . . NG
(Display example)
“QA02 NG”, “H001 NG”, “Q501 NG” etc.
Note: The indication of failure place is only one place though failure places are plural. When
repair of a failure place finishes, the next failure place is indicated. (The order of priority of
indication is left side.)
���
Sync. signal check
Green display ..... Normal
Cyan display ...... No check
Red display ........ NG
MAIN ....... Main sync
SUB ........ Sub sync (when turn on the PIP)
���
ID code for TV set
���
Version of "EEP"
���
Data for "OPT"
Summary of Contents for 30H83
Page 31: ... 31 32 SIGNAL BOARD PD1086B BOTTOM FOIL SIDE ...
Page 32: ... 33 34 POWER DEF BOARD PD1087B BOTTOM FOIL SIDE ...
Page 33: ... 35 36 CONT BOARD PD1266 1 BOTTOM FOIL SIDE ...
Page 35: ... 39 CRT D SVM BOARD PD1173C BOTTOM FOIL SIDE ...
Page 40: ...TOSHIBA CORPORATION 1 1 SHIBAURA 1 CHOME MINATO KU TOKYO 105 8001 JAPAN ...