67
Deutsch
English
4.6.2 Cruise 4.0 FP
Cruise 4.0 FP operates with a power supply of between 42 V and 58 V (referring to nomi-
nal voltage). This means that it has to be operated with at least two Power 26-104 lithium
batteries.
Connecting the Cruise 4.0 FP to two Power 26-104 follows the same steps as the con-
nection of the Cruise 2.0 FP, (refer to chapter 4.6.1). However, you must connect two
Power batteries in series to provide the Cruise 4.0 with the necessary 48 V. Connect the
positive terminal of the first battery to the negative terminal of the second battery, using
the bridge cable provided. Also connect the two batteries‘ data sockets together with the
supplied data cable.
Connecting of Cruise 4.0 FP to two Power 26-104 batteries
Step 6: connection of
high current plug
Step 4: switch main switch
of cable set to “OFF”
Step 1:
Connection of
data cable 1
(scope of supply
Power 26-104)
Step 5:
Connection of
positive and
negative termi-
nal posts (see
positive and
negative pola-
rity on imprint
on battery and
terminal posts)
negative terminal post
data socket 2
data socket 1
positive terminal post
Step 2:
Connection of data
cable 2 (scope of sup-
ply Power 26-104)
Step 3:
Connection
of data cable 2
(scope of supply
Cruise)