![Toro Groundmaster 31900 Service Manual Download Page 41](http://html1.mh-extra.com/html/toro/groundmaster-31900/groundmaster-31900_service-manual_1133559041.webp)
Machine and Engine Faults
Machine Faults
Machine faults are generated by the TDM display/controller to identify an
electrical system malfunction (fault) that occurs during machine operation. The
fault IDs conform to SAE J2012 standards. When a fault occurs, the bi-color
LED on the TDM display/controller panel will flash red and a code for the active
fault will appear along the bottom of the TDM display/controller screen. If more
than one fault is active, their codes will scroll across the bottom of the TDM
display/controller screen one-by-one. Depending on the severity of the fault,
a STOP icon may also be displayed.
Recent faults can be viewed via the TDM display/controller screen. A code
appears after each fault indicating which controller generated the fault. For
example: C14C5:T1 is a PTO fault generated by the T1: TDM
Machine Faults
Fault
ID
Fault Title
Fault
Condition/Circuit
Description
Additional Notes
Service Actions
B1027
Speed
Increase/Decrease
Switch Broken
The speed
increase and
speed decrease
Inputs are active
at the same time.
Speed
increase/decrease
is disabled.
1.
Test the speed increase/decrease switch.
2.
Check the wire harness connectors
(P100, P106) for damage or corrosion
and clean or repair if necessary.
3.
Check the circuit wiring.
B105D
Cutting unit
Raise/Lower Switch
Broken
The cutting unit
raise and deck
lower Inputs
are active at the
same time.
Cutting unit
raise/lower is
disabled.
1.
Test the cutting unit raise/lower switch.
2.
Check the wire harness connectors
(P100, P33) for damage or corrosion and
clean or repair if necessary.
3.
Check the circuit wiring.
C1013
Engine Run Output -
Short to Battery
Low current
detected on the
engine run output
circuit. Indicates
a short to a high
(+) source.
The short could be
to battery voltage
or to another signal
that is in a high (+)
state.
1.
Check the wire harness connectors for
damage or corrosion and clean or repair
if necessary.
• Model 31900/01 (P100, P19, P202,
P203)
• Model 31902/03 (P100, P19, P53, P55,
P01)
2.
Test the engine run output circuit wiring.
3.
Test the engine run output circuit
components.
• Model 31900/01 (start interlock relay,
fuel pump, fuel solenoid)
• Model 31902/03 (start interlock relay,
fuel pump, alternator)
4.
Swap the TDM controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
Groundsmaster
®
3200, 3300 and 3310
Page 3–5
Troubleshooting: Cutting Unit (or attachment) Problems
19240SL Rev A
Summary of Contents for Groundmaster 31900
Page 4: ...Reader Comments Page 4 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Page 16: ...Safety Safety and Instructional Decals Page 1 8 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Page 86: ...Engine Service and Repairs Page 4 24 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Page 332: ...Operator Cab Service and Repairs Page 9 18 Groundsmaster 3200 3300 and 3310 19240SL Rev A...
Page 355: ......