Inspecting, Maintaining, and Testing the Batteries (Model 04580) (continued)
IMPORTANT
Many locally available battery load testers do not, have any
adjustment on the load that is put on the battery. Results received
from using load testers should follow the recommendations of the
load tester manufacturer.
Charging the Batteries (Model 04580)
The batteries may be individually charged with a 12V charger rated for operation
with absorbed glass mat (AGM), valve regulated lead acid (VRLA) batteries. The
voltage of this battery type is slightly lower than flooded lead acid batteries.
Maximum charge voltage should be limited to 14.8 VDC. Maximum charge
current should be limited to 2.4 amps.
IMPORTANT
Follow the manufacturer's instructions when using a battery charger.
Operating the machine should charge the 12V system and the 48V system
batteries.
Electrical System: Batteries (Model 04580)
Page 5–110
Greensmaster® eTriFlex 3360 and 3370
19239SL Rev B