Using the Smart
Controller/Electronic Depth
Control
Hour Meter/Tine Engagement
Display
The smart controller/electronic depth control monitors
the overall electrical system and displays information
in the hour meter/tine engagement display. The
controller displays machine hours, interlock status,
and maintenance reminders.
Screen Icons
The information screen uses the following icons:
Aerating Hours
Parking brake
Battery Voltage
Engine Oil Maintenance
Hour Meter
Transmission Oil
Maintenance
Voltage Error
Valve Solenoid Error
Valve Solenoid Connection
Error
Information Screens
The main information screens include:
•
The Startup Screens
•
The Default Screen (engine-on)
•
The Tine Engagement Display
•
Maintenance Reminders and Alerts
•
Alerts and Error Messages
Start-up Screens
When the key is switched from O
FF
to R
UN
position,
the following screens display for 2 seconds:
Note:
The LED status light changes from red to
orange to green.
The first screen displays the firmware version.
g212116
Figure 15
The second screen displays the aeration hours.
g212114
Figure 16
The third screen displays the electrical system voltage.
g212115
Figure 17
19