QUICK REFERENCE − DECO 13A
en 300417 − 04/08
12
M/S
Grp.
Function
Code
G550
Cancelling of polygon mode S5 spindle activa-
ted over G551. Polygon mode to be cancelles
over a M505 or M503 S function.
G551
Activation of S5 spindle (identified by hundreds)
in polygon mode
R2 Q−0 does not reverse the sense of rotation
R2 Q−1 reverses the sens of rotation
G900
Initialize spindles with settings specified for part
G901
Initialize sequences
*
Functions active by default for new operation
Grp.
Function Group Nb.
M
Modal:
Function remains active until replaced by another function of
same group
S
Sequential:
Function remains active in programmed segment only.