1E04

2102

Possible Controller fault

Replace Controller if not cleared by disconnecting batteries for 1 min

2103

2C00

Low voltage warning

Recharge batteries immediately

2C01
2C02

Dependent on programming

Recharge batteries immediately

2D01

Possible Controller fault

Replace Controller if not cleared by disconnecting batteries for 1 min

2F01

Throttle in drive position during

switch on

Incorrect operation of machine.  Otherwise check the mechanical

condition of the throttle mechanism. Otherwise check for wiring short

circuits on the 20 way connector on the Trio, the 16 way connector on

the LCD (if used) and the wiring to the front panel switches & controls

and those switches & controls themselves.

3100

All 310x codes - Probable short

circuit of output device or

wiring - can sometimes cause

permanent Controller fault.

Check the Traction, Brush and Vac motor connections on the Trio and

check the wiring from these connectors down to the Traction, Brush and

Vac motors checking connections all the way and also checking for

short circuits.  Check for wiring short circuits or broken wires on the 14

way connector on the Trio and the wiring elsewhere on the machine.

Otherwise replace Controller.

3101
3102
3103
3104
3105
3201

Possible Controller fault

Replace Controller if not cleared by disconnecting batteries for 1 min

3210
3211
3212
3213
3214
3601

Possible Controller fault

Replace Controller if not cleared by disconnecting batteries for 1 min

3602
3603
3608
3609

360A
360B
360C
360D

360E

7000

All 70xx codes – Check wiring

of brake and freewheel switch

Check for wiring short circuits on the 20 way connector on the Trio, the
16 way connector on the LCD (if used) and the wiring to the ffreewheel

switch and the switch itself..  Check the Traction motor connection on

the Trio and check the wiring from this connector down to the

electromagnetic brake on the Traction motor and check connections all

the way. Can be caused by excessive pushing or rolling down a slope

or incorrect operation of the machine.

7001

7500

Wiring fault on 6-way serial link

between Trio and LCD

Check the wiring and connectors on the 6 way connections on the Trio

and LCD

7501

LCD memory corrupt

Disconnect batteries and wait for 1 min before re-applying power

7600

Open circuit on brush motors

or brush motor wiring

Check the Brush motor connection on the Trio and check the wiring

from this connector down to the Brush motor and checking connections

all the way.  Otherwise possible Brush motor fault.

7601

Brush current overload

(“thermal” trip)

Incorrect programming, incorrectly specified Brush motor, Brush motor

developing a fault, excessive resistance on brushes or brushes pushing

down too hard on floor.

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for Floorkeeper 99328

Page 1: ...For Parts List see L9332EDP Effective 11 7 2005 Form No L9332ED Revised 11 05 2006 Tornado Industries All rights reserved TORNADO INDUSTRIES 7401 W LAWRENCE AVENUE CHICAGO IL 60706 708 867 5100 FAX 7...

Page 2: ...2 NOTES h t t p s h a r r i s s u p p l y i n d c o m T o O r d e r P a r t s C a l l 6 0 8 2 6 8 8 0 8 0...

Page 3: ...INTRODUCTION 13 BATTERY CARE 13 BATTERY CHARGING 15 SQUEEGEE BLADES 16 SQUEEGEE ADJUSTMENT 17 VACUUM AND WATER RECOVERY SYSTEM 18 SOLUTION AND RECOVERY Vacuum TANKS 18 VACUUM MOTOR 19 WHEELS 19 LUBRI...

Page 4: ...hs labor OR 1000 hours of operation whichever comes first Warranties on the 75 140 90 140 are 24 months parts 12 months labor OR 1 000 hours of operation whichever comes first 3 All non wear item part...

Page 5: ...ge Floorkeeper Automatic Scrubber was designed and built to exceed your needs for durability and serviceability in demanding commercial environments This manual is designed to instruct your personnel...

Page 6: ...Button 5 Brush Position Switch Rear Controls 6 Adjustable Solution Control 7 Dual Drive Levers 8 Dual Reverse Buttons 9 Emergency Stop Switch 10 Key Lock 11 Circuit Breaker 12 Squeegee Control Lever...

Page 7: ...ique screens Each screen displays a different set of icons and numerical readouts to give you useful information about your Long Range Floorkeeper s operating status For particulars on diagnostic faul...

Page 8: ...y as shown in bottom photo or refer to chart located under the hood Ensure that positive and negative terminals are positioned and connected correctly CAUTION Observe polarity Place battery terminal p...

Page 9: ...queegee assembly Make sure the black metal bracket on the squeegee assembly is aimed forward toward the concave side of the squeegee Lift the squeegee bracket and washers if present and slide the sque...

Page 10: ...htly Refer to the Maintenance section to properly adjust the squeegee position for best wiping performance Never store machine with squeegee in down position This can damage the flexible blades Always...

Page 11: ...e brush heads using the switch on the control panel 2 Place the brushes or pad holders under the brush cover Center the brushes on the brush couplers Pull up to lock in place 3 Check to see that the t...

Page 12: ...recovery tank before filling solution tank This will eliminate overfilling of recovery tank Lift solution tank cover and fill 3 Close top covers by pushing covers down You are now ready to operate yo...

Page 13: ...quantities of running water for 15 minutes SKIN Flush area with plentiful amounts of running water INGESTION Give milk to drink DO NOT induce vomiting call a physician SPILLS Wash with water or neutr...

Page 14: ...y caps Using baking soda or ammonia and water solution saturate a cloth and wring until drip dry Use this cloth to wipe the battery tops 1 The battery terminals and connections need to be coated with...

Page 15: ...AS DO NOT DISCONNECT CHARGER DC OUTPUT TERMINALS FROM BATTERY WHEN CHARGER IS ON THE RESULTING ARCING AND BURNING COULD CAUSE THE BATTERY TO EXPLODE KEEP SPARKS FLAME AND SMOKING MATERIALS AWAY FROM B...

Page 16: ...d remove the entire assembly disconnect the vacuum hose loosen both star handles and slide the squeegee assembly out Remove both guide wheels and end caps Pull each blade out from one end and slide it...

Page 17: ...appear evenly loaded readjust the squeegee assembly using the directions below Loosen the two rocker thumbscrews Hold the squeegee and rotate it forward or rearward until the squeegee blades contact...

Page 18: ...o dry when not in use A liquid shutoff is built into the filter system to prevent overfilling tank Do not disassemble or modify the white plastic float or vacuum motor damage may result Solution and R...

Page 19: ...rrosion of vacuum motor Vacuum Motor To service vacuum motor which is located above re covery tank 1 Disconnect vacuum hose clamp 2 Remove four screws 3 Disconnect wires and remove cover 4 Remove vacu...

Page 20: ...eplacement brushes need to be inspected and changed more often due to commutator wear Always permanently record any brush inspections and replacements you make Don t attempt to use the Motor Fault Err...

Page 21: ...shutoff closes to prevent water from entering vacuum motor 2 Loose hose on float filter creating an air leak 3 Clogged filter 4 Clogged stand pipe near filter Remove cap to inspect and clean with hose...

Page 22: ...ocedures will avoid problems with the recovery system requiring outside repair service Always be very sure the vacuum system is clear of any blockage before calling for service Poor Solution Flow If a...

Page 23: ...ries Check the lights on the battery charger after charger shuts off A Green light Batteries are fully charged and are in good condition B Amber light All cells are OK but the total battery capacity i...

Page 24: ...etal and excessive heat away from batteries 7 Use TORNADO charger with correct voltage and current rating TROUBLESHOOTING PERFORMANCE SYMPTOMS Poor Solution Pickup Vac motor not running Vac filter is...

Page 25: ...0811 0812 0813 0814 0815 0816 0817 0818 0A01 Possible Controller fault Replace Controller if not cleared by disconnecting batteries for 1 min 0B0B Possible Controller fault Replace Controller if not c...

Page 26: ...nnecting batteries for 1 min 3210 3211 3212 3213 3214 3601 Possible Controller fault Replace Controller if not cleared by disconnecting batteries for 1 min 3602 3603 3608 3609 360A 360B 360C 360D 360E...

Page 27: ...Trio and check the wiring from this connector down to the Traction motor and checking connections all the way Otherwise possible Traction motor fault 7801 Possible short circuit on Traction motor or...

Page 28: ...grease gun supplied with Floorkeeper 2 Check the specific gravity of fully charged battery cells allow a 30 minute cool down after charging specific gravity should be 1 270 to 1 280 MONTHLY MAINTENAN...

Reviews: