2. Install the left side panel (viewed from the front), with
the flanges overlapping the front and rear panels. The
right side panel will be left off for now to allow access
to the bottom of the machine.
Note that this side panel has a small cable carrier on the
inside of the frame to carry cables from the machine
arm to the electrical cabinet.
3. Hang the cable track mounts on the two M8 button head
mounting screws.
4. Remove the top cover from the cable track (4x M3
screws). It will be reinstalled after hanging the electrical
cabinet.
5. Install the cable track to the mounts with four M6 button
head cap screws.
6. Hang the electrical cabinet from five M6 screws, leaving
the one nearest the pass-through hole for electrical
wires off (this is where a ground wire will be attached).
4.7 ATTACH THE CABLE GUARD
1. Unwrap the flexible black cable guard from where it is
bundled on the side of the gantry and lay it out onto the
cable track above the electrical panel.
©Tormach® 2020