INPUT VOLTAGE:

120VAC  50/60Hz, 4VA

CONTACT CONFIGURATION:

SPDT (Dry Contact)

SWITCH RATING:

16A 120VAC Resistive, 8A 120VAC General Purpose, 1/2HP @120VAC

NUMBERS OF EVENTS:

8 ON/OFFs

IMPORTANT SAFETY INSTRUCTIONS

  

READ & FOLLOW ALL INSTRUCTIONS – SAVE THESE INSTRUCTIONS 

ATTENTION: Read carefully before attempting to install this control. Failure to comply with instructions could result in personal injury and/or property damage!

This control must be installed in accordance with National and Local Electrical Codes. Disconnect power at main panel before installing or servicing this device. 

Do not exceed the ratings of this device, and current capacity of conductors. This control should not operate any equipment which would cause bodily injury or 

property damage should it be activate unexpectedly.

BATTERY INSTRUCTIONS

The lithium battery inside timers will be covered by a very thin insulation film which should be  

removed while/after installation

PROGRAMMING THE TIMER

KEYPAD FUNCTIONS DESCRIPTION:

 

TIMER:

 To set/review/modify events. 

MANUAL:

 Changes the load control to either 

ON, AUTO, or OFF

.  

CLOCK:

 To enable clock set and exit programming.

DAY:

 To set the day(s). 

HOUR:

 To set hour.

MIN:

 To set minute.  

RESET:

 Resets the timer and clears all memory. 

SETTING THE CLOCK:

 Press and hold 

CLOCK

 button and then press 

DAY

HOUR

, and 

MIN

 buttons to set the current time and day-of-the-

week.

PROGRAMMING SCHEDULE:

  

NOTE: Please press the RESET button prior to installation and initial 

programming.

1: Press TIMER button: This is the first ON event.  

The 

LCD

 should show:

2: Press 

DAY

 button to select the desired day-of-the-week setting.  

Each press advances the selection for each of the possible 15 daily 

combinations.

3: Press 

HOUR

 and

 MIN

 

buttons respectively to set 

the event time.

4: Press the 

TIMER

 button to 

store this event, and advance

to the next event, the first 

OFF

 

event. The 

LCD

 should show:

5: The unit will alternate 

ON

 and 

OFF

 events every time you press the 

TIMER

 button. Repeat steps 2-4 for each required event. After you’ve 

finished programming the timer, press 

CLOCK

 button to exit program-

ming mode.

TO REVIEW/MODIFY PROGRAMS:

 

Press 

TIMER

 button.  Each time you press the 

TIMER

 button you ad-

vance between alternate 

ON

 and 

OFF

 events, numbered 1 to 8 and 

then back to 1.  Modify events as needed by using 

DAY

MIN

, and 

HOUR

 buttons as before.  Press 

TIMER

 button to store the changes and 

advance to the next event.

OVERRIDE:

 

In the 

AUTO

 mode, you can turn the load either 

ON

 or 

OFF

 by press-

ing 

MANUAL

 button.  Using the same button you can return back to 

the 

AUTO

 mode to resume schedules.

LOAD STATUS INDICATORS:

 

There is an LED, marked “Power” to indicate current load status.

RANDOM SCHEDULES OVERRIDE:

 

To execute a random schedule (

ON

 and 

OFF

 time varies in a random 

pattern every 10 to 120 minutes) press and hold 

DAY

 button then 

press MIN button. While in the Random mode, the 

LCD

 will display the 

following symbol:   

To return to normal schedules, press and hold 

DAY

 button, then press 

MIN 

button.

LI-797(C)                                                         

888.500.4598 • www.nsiindustries.com

®

 

OFF 

- - : - -

 _

 

ON 

- - : - -

  _ _

NSi Industries, LLC • 888.500.4598 • www.nsiindustries.com

1

MO

TU

WE

TH

FR

SA

SU

2

MO

3

TU

4

WE

5

TH

6

FR

7

SA

8

SU

9

MO

TU

WE

TH

FR

10

SA

SU

11

MO

TU

WE

TH

FR

SA

12

MO

TU

WE

13

TH

FR

SA

SU

14

MO

WE

FR

15

TU

TH

SA

TEMPORIZADOR DIGITAL DE 7 DÍAS

E315214

Reviews: