9
3. Firmly close the Release Valve by turning it
clockwise.
4. With the release valve closed, connect the air inlet
fitting, to shop air supply.
A.Supply air to pump by pushing the air trigger valve
on the shop press hose connection. Allow the
pump to work for ten seconds.
B.After 10 seconds release the air trigger valve, so
air supply stops to pump.
C.Then pump the handle for ten pumps.
2. Connect the air inlet fitting, to shop air supply.
A. Supply air to pump by pushing the air trigger
valve on the shop press hose connection. Allow
the pump to work for ten seconds.
B. After 10 seconds release the air trigger valve, so
air supply stops to pump.
C.Then pump the handle for ten pumps.
SYSTEM AIR PURGE PROCEDURE
IMPORTANT: BEFORE FIRST USE
All numbers in parenthesis () refer to the index number from the parts breakdown.
Perform the following Air Purge Procedure to remove any air that may have been introduced into the hydraulic
system as a result of product shipment and handing. This step is to be completed without and weight on the
jack.
1. Open the Release Valve by turning counter-
clockwise to release the pressure in the pump
and hose.
Air fitting inlet