9. Precautions of using LCD Modules

Mounting

-

Mounting must use holes arranged in four corners or four sides.

-

The mounting structure so provide even force on to LCD module. Uneven force (ex. Twisted stress)
should not applied to the module. And the case on which a module is mounted should have sufficient
strength so that external force is not transmitted directly to the module.

-

It is suggested to attach a transparent protective plate to the surface in order to protect the polarizer.
It should have sufficient strength in order to the resist external force.

-

The housing should adopt radiation structure to satisfy the temperature specification.

-

Acetic acid type and chlorine type materials for the cover case are not desirable because the former
generates corrosive gas of attacking the polarizer at high temperature and the latter causes circuit
break by electro-chemical reaction.

-

Do not touch, push or rub the exposed polarizers with glass, tweezers or anything harder than HB
pencil lead. Never rub with dust clothes with chemical treatment. Do not touch the surface of
polarizer for bare hand or greasy cloth.(Some cosmetics deteriorate the polarizer.)

-

When the surface becomes dusty, please wipe gently with absorbent cotton or other soft materials
like chamois soaks with petroleum benzine. Normal-hexane is recommended for cleaning the
adhesives used to attach front / rear polarizers. Do not use acetone, toluene and alcohol because
they cause chemical damage to the polarizer.

-

Wipe off saliva or water drops as soon as possible. Their long time contact with polarizer

Operating

-

The spike noise causes the mis-operation of circuits. It should be within the

±

200mV level (Over and

under shoot voltage)

-

Response time depends on the temperature.(In lower temperature, it becomes longer.)

-

Brightness depends on the temperature. (In lower temperature, it becomes lower.) And in lower
temperature, response time(required time that brightness is stable after turned on) becomes longer.

-

Be careful for condensation at sudden temperature change. Condensation makes damage to
polarizer or electrical contacted parts. And after fading condensation, smear or spot will occur.

-

When fixed patterns are displayed for a long time, remnant image is likely to occur.

-

Module has high frequency circuits. Sufficient suppression to the electromagnetic interference shall
be done by system manufacturers. Grounding and shielding methods may be important to minimized
the interference

Electrostatic Discharge Control

Since a module is composed of electronic circuits, it is not strong to electrostatic discharge. Make certain
that treatment persons are connected to ground through wrist band etc. And don’

t touch interface pin

directly.

Strong Light Exposure

Strong light exposure causes degradation of polarizer and color filter.

Storage

When storing modules as spares for a long time, the following precautions are necessary.

-

Store them in a dark place. Do not expose the module to sunlight or fluorescent light. Keep the
temperature between 5

°

C and 35

°

C at normal humidity.

-

The polarizer surface should not come in contact with any other object. It is recommended that they
be stored in the container in which they were shipped.

Protection Film

-

When the protection film is peeled off, static electricity is generated between the film and polarizer.
This should be peeled off slowly and carefully by people who are electrically grounded and with well
ion-blown equipment or in such a condition, etc.

-

The protection film is attached to the polarizer with a small amount of glue. If some stress is applied
to rub the protection film against the polarizer during the time you peel off the film, the glue is apt
tore main on the polarizer. Please carefully peel off the protection film without rubbing it against the
polarizer.

-

When the module with protection film attached is stored for a long time, sometimes there remains a
very small amount of glue still on the polarizer after the protection film is peeled off.

-

You can remove the glue easily. When the glue remains on the polarizer surface or its vestige is
recognized, please wipe them off with absorbent cotton waste or other soft material like chamois
soaked with normal-hexane.

Transportation

The LCD modules should be no falling and violent shocking during transportation, and also should avoid
excessive press, water, damp and sunshine.

 

ZZZWRSZD\GLVSOD\VHX

LQIR#WRSZD\GLVSOD\VHX

 

Summary of Contents for LMT056DIDFWD-ABN

Page 1: ...l Prepared by Yang Checked by Approved by Date 2012 08 01 Date Date Rev Descriptions Release Date 0 1 Preliminary new release 2012 08 01 0 2 Typing Correction on Terminal Function 2012 11 15 ZZZ WRSZD...

Page 2: ...aximum Ratings 5 5 Electrical Characteristics 5 5 1 DC Characteristics 5 6 AC Characteristics 6 6 1 TFT Controller Timing Characteristics 6 6 2 TFT Controller Reset Timing 7 7 Optical Characteristics...

Page 3: ...General Specification beat Signal Interface 8bit data 1bit address Display Technology TFT active matrix Display Mode Transmissive Normal White Screen Size Diagonal 5 6 Outline Dimension 155 2 x 109 0...

Page 4: ...VDD I Positive Power Supply 5 0V 4 5 D C I Register Select D C 0 command D C 1 data or parameter 6 CS I Chip Select signal 7 RESET I Reset signal RESET 1 normal RESET 0 reset execute 8 D0 I O 8bit Da...

Page 5: ...ce value 4 Any Stresses exceeding the Absolute Maximum Ratings may cause substantial damage to the device Functional operation of this device at other conditions beyond those listed in the specificati...

Page 6: ...read cycle 113 9 tMCLK ns Read 113 9 tMCLK ns Address Setup Time tAS 7 8 ns Address Hold Time tAH 9 ns Write Data Setup Time tDSW 11 5 ns Write Data Hold Time tDHW 7 8 ns Write Low Time tPWLW 28 ns R...

Page 7: ...Name LMT056DIDFWD ABN Manual Rev0 2 Page 7 of 14 6 2 TFT Controller Reset Timing VSS 0V VDD 5 0V TOP 25 C Item Symbol MIN TYP MAX Unit Reset setup time trs 2 ms Reset pulse trst 0 2 ms Reset hold tim...

Page 8: ...1 Color chromaticlty WX 0 26 0 31 0 26 WY 0 28 0 33 0 38 Luminance L 350 cd m 2 4 Luminance uniformity YU 70 75 4 Note 1 Definition of Contrast Ratio The contrast ratio could be calculate by the foll...

Page 9: ...eter Command Code and Parameters are 8bit only Number of Parameters is depends on Command type some of the command followed with no parameter Se q D C RD WR Lo byte D7 D0 1 0 1 Command code 2 1 1 Para...

Page 10: ...write_memory_start Transfer image information from the host processor interface to the SSD1963 starting at the location provided by set_column_address and set_page_address 0x2E read_memory_start Trans...

Page 11: ...lcd_gen3 Get the current settings of LCD signal generator 3 0xC8 set_gpio0_rop Set the GPIO0 with respect to the LCD signal generators using ROP operation No effect if the GPIO0 is configured as gener...

Page 12: ...set_lcd_mode SdData 0x24 24bit disable FRC or dithering DCLK rising edge SdData 0x20 HSYNC active lo VSYNC active low default TFT m SdData 0x02 SdData 0x7f panel size 640 1 SdData 0x01 SdData 0xdf pan...

Page 13: ...s damage to polarizer or electrical contacted parts And after fading condensation smear or spot will occur When fixed patterns are displayed for a long time remnant image is likely to occur Module has...

Page 14: ...ots N 2 Dark Dots N 3 Total Bright and Dark Dots N 4 Note 1 The definition of dot The size of a defective dot over 1 2 of whole dot is regarded as one defective dot 2 Bright dot Dots appear bright and...

Reviews: