Toptech TT-P-411 User Manual Download Page 1

This thermostat requires 24 Volt AC Power or two (2) properly installed 
“AA” Alkaline batteries for proper operation. When connecting 24 Volt 
AC Power the batteries may be installed as a backup. 

For use only as described in this manual. Any other use will 

void warranty.      

    

TT-P-411

Single Stage Heat / Cool

Conventional and Heat Pump

1

  

Specification

Installation

Setting User Options

4

  Setting Your Program 

 Schedule

5  

Operating Your Thermostat

6

  Additional Operation Features

7

  Thermostat Maintenance

Warning

Turn off power to the heating or cooling 

equipment before installation.

Attention

For installation by experienced service 

technicians only. Follow applicable codes.

TT-P-421

Up to 2 Heat / 1 Cool

Conventional and Heat Pump

Read all instructions before proceeding.

   This thermostat is compatible with:

   

• Single stage heat / cool conventional and heat pump systems

   

• Conventional systems up to 2 heat / 1 cool 

(TT-P-421 only)

   

• Single compressor heat pump systems with an auxiliary heat stage

 (TT-P-421 only)

   

• 250 – 750 millivolt heat only systems

  

Electrical and control specifications:

   

• Electrical Rating:  24 Volt AC

   

• 1 amp maximum load per terminal

   

• AC Power:  18 – 30 Volts AC

   

• DC Power:  3.0 Volt DC (2 “AA” Alkaline Batteries Included)

   

• Control Range:  45° – 90° F (7° – 32° C)

   

• Temperature Accuracy:  +/- 1° F (+/- .5° C)

   Terminations

   

• TT-P-411 – Rc, Rh, O, B, Y, W, G, C

   

• TT-P-421 – R, O, B, Y1, E/W1, G, W2, C

1

Specifications

TTP-100-02

Model number is located on 

thermostat sub-base.

 

 

Programmable Thermostats

®

Summary of Contents for TT-P-411

Page 1: ...service technicians only Follow applicable codes TT P 421 Up to 2 Heat 1 Cool Conventional and Heat Pump Read all instructions before proceeding This thermostat is compatible with Single stage heat c...

Page 2: ...ir circulation and maintains an aver age room temperature Avoid installation in locations where the thermostat can be affected by drafts dead air spots hot or cold air ducts sunlight appliances concea...

Page 3: ...ical Wiring Configurations NOTE The Installer Switch option will be configured in the next step Conventional Systems NOTES Conventional Systems 1 If batteries are installed the 24 Volt AC common conne...

Page 4: ...option will be configured in the next step Heat Pump Systems 1 HEAT 1 COOL No Auxiliary Heat Set Installer Switch to HP Rh 24 Volt AC Power Rc Connected to Rh with supplied Jumper Wire O or B Changeo...

Page 5: ...ber of days before 90 180 the thermostat will flash a Service Filter reminder in the display 5 REC OF Disables adaptive early recovery mode REC ON Enables adaptive early recovery mode Table of User Op...

Page 6: ...ming is necessary Programming a 5 2 Day Residential Schedule The 5 2 day residential programming mode allows you to program Monday Friday with one 4 event schedule and then allows you to change Satur...

Page 7: ...ted with the system switch Setting the Fan Control Mode The Fan Control has 2 modes of operation AUTO and ON The mode can be selected by moving the FAN switch AUTO The system fan will run only when yo...

Page 8: ...es annually or if the thermostat will be unattended for an extended period of time Thermostat Cleaning Never spray any liquid directly on the thermostat Using a soft damp cloth wipe the outer body of...

Page 9: ...control R gimen de electricidad 24 voltios CA Carga m xima de 1 amperio por terminal Energ a de CA 18 30 V de CA Energ a de CC 3 0 voltios de CC 2 bater as alcalinas tipo AA incluidas Rango de control...

Page 10: ...stale la sub base 2 Suministre energ a 3 Conecte los cables 4 Configure los interruptores de instalaci n 5 Fije el termostato a la sub base Instale la sub base Retire la sub base del cuerpo del termos...

Page 11: ...ota 1 3 Configuraciones t picas de cableado NOTA La opci n Interruptor de instalaci n se configurar en el siguiente paso Sistemas convencionales Transformador sencillo con 2 etapas de calefacci n 1 et...

Page 12: ...rmador a 24 voltios de CA nota 1 NOTAS Sistemas de bomba de calor 1 Si las bater as est n instaladas la conexi n com n a 24 voltios de CA es opcional 2 Seleccione O para aire acondicionado activo o B...

Page 13: ...as que deben transcurir antes de que el termostato emita de forma intermi tente un recordatorio de servicio en la pantalla 5 REC OF Deshabilita el modo de recuperaci n anticipada adaptable REC ON Habi...

Page 14: ...00 p m Calefacci n 21 C 70 F Aire acondicionado 25 C 78 F Hora 8 00 a m Calefacci n 17 C 62 F Aire acondicionado 29 C 85 F Hora 6 00 a m Calefacci n 21 C 70 F Aire acondicionado 25 C 78 F Hora 10 00 p...

Page 15: ...switch del sistema Configuraci n del modo de control del ventilador El control del ventilador tiene 2 modos de funcionamiento AUTO Au tom tico y ON Encendido El modo puede ser seleccionado al mover e...

Page 16: ...e ning n l quido directamente sobre el termostato Limpie la parte de exterior del termostato con un pa o suave y h medo Nunca utilice limpiadores abrasivos para limpiar el termostato Guarde este manu...

Reviews: