74
2. Reinstall the screws and lockwasher.
3. Connect the prox reader cable to the display subassembly.
Figure 7.11
ML II/ RCU II Div2 Cover with Slotted Card Holder Thinline II (Obsolete)
Slotted Card Holder Mounted TWIC Reader (Obsolete) Removal and Replacement:
7.5.4
Replacement part number: 4726
Removal:
1. Disconnect the prox reader cable from the display subassembly.
2. Remove the 2 screws attaching the card reader.
3. Remove the prox reader.
Installation with Older Part:
1. Replace the card reader. Orient the LED toward the top.
2. Reinstall the screws and lockwasher.
PROX
READER