1 x Ultrasonic Cool Mist Humidifier
1 x User Guide Kit
WHAT’S IN THE BOX
For a deep cleaning of the Top Cap part, rotate the Top Cap counterclockwise to
detach from the Tank Cover, pull out the Mist Shaping Ring. Take the Float out.
Wash all parts under tap water thoroughly and wipe clean. Pay attention to the
direction of the Mist Shaping Ring and the Float when reassembling all parts.
Pay attention when lifting the top cover in case of water drops on the surface.
Empty water from the water tank away from the air outlet.
The ceramic disc should not come in contact with any hard or sharp objects.
To remove possible buildup, rinse with a white vinegar and water solution.
Dry thoroughly with a soft cloth.
Do not use strong cleaning agents.
Make sure the power cord and plug are let dry before next use.
Notes:
Model
Water Tank Material
Working Voltage
Power Consumption
Frequency
Water Tank Capacity
Mist Level
Run Time per Tank
Timer Options
Humidifying Capacity
Operating Noise
Low Water Level Protection
Dimensions
Net Weight
TPHM002
PP
AC110V, 60Hz
25W
1.7±0.1MHz
2.8L / 94oz
3 levels (Low / Medium / High)
Up to 12H (high mist level)
Up to 16H (medium mist level)
Up to 24H (low mist level)
3 options (2H / 4H / 8H)
Up to 6.8±1.4oz/h
≤38dB (from 3.3ft away)
Supported
7.6 x 7.1 x 9.8in
2.6lbs
SPECIFICATIONS
•
•
•
•
•
•
•
•
•
•
•
•
Water vapor and
humidity are not
produced.
Air blows but water
vapor is not
produced.
Humidity level is
low.
The mist has a bad
smell.
White dust is
forming on nearby
furniture.
Power plug - unplug cord from the
humidifier, try again.
Power failure - when power is restored, try
again.
Tank cover installation - make sure tank
cover is attached correctly.
The surface of the nebulizer is dirty - wipe
with soft cloth.
•
•
•
Dirty tank - wash out tank and try again.
Dirty nebulizer – wipe clean the part with a
soft cloth.
Use of distilled water - 3 pinches of salt
must be added to distilled water, stir to
ensure thorough mixing. Caution: Add salt
only by pinch, because too much salt added
to the water can cause excessive boiling,
blowing of fuse, or a stuck circuit breaker.
•
•
The surface of the nebulizer is dirty - Wipe
the part with a soft cloth.
The water in the unit is too cold - replace
with cool, but not cold, water.
• Poor maintenance or dirty water - clean the
tank thoroughly according to instructions
above and fill with fresh water.
• Hard water may deposit a dust-like residue.
In addition, dust in the air may settle due to
the added humidity in the room.
TROUBLESHOOTING