Troubleshooting 

Have a multi-meter to check voltage and continuity. Use caution when checking high voltage terminals. 

Symptom 

Possible Solution(s) 

The opener does  not 
run.  Power LED is 
OFF. 

1. Check the input voltage of the control board. It should be local AC 
electricity. 
2. The power switch is OFF. Make sure the power switch is ON. 
3. Check the fuse in the control board. Replace the fuse if it was burnt out. 
4. Check the control board. Replace the control board as necessary. 

The opener does  not 
run. Power LED is 
ON. 

1. Ensure the remote control has been programmed to the control board 
before operating. 
2. The thermal protector is working because the high temperature after long 
working time. Please wait for 20 minutes to let the motor become cold. 
3. Check the installing position of the magnets. The opener would not run if 
both of the limit switches are activated by one magnet.   
4. Check the limit switch.  Remove  the wire connection of the limit switch 
which is connected to the 9#, 10#, and 11# terminals of the control board and 
then try it again.  Replace the limit switch if the motor could run in both 
directions. 
5. Check the control board. Replace the control board as necessary. 

Remote control does 
not work. 

1. The indicator light of remote control is not on. Check the battery in your 
remote control. Replace the battery as necessary. 
2. The distance you use the remote is too far away from the opener. Try it 
again closer. 
3. Remote control is not suitable for receiver. After making sure the codes are 
correct, erase remote controls and then re-program the codes in the device. 
4. Check the control board. Replace the control board as necessary. 

The gate opens, but 
stops and will not 
return. 

1. Check the installing position of the magnets. The opener would not run if 
both of the limit switches are activated by one magnet.   
2. Check the limit switch.  Remove  the wire connection of the limit switch 
which is connected to the 9#, 10#, and 11# terminals of the control board and 
then try it again.  Replace the limit switch if the motor could run in both 
directions. 
3. Check the control board. Replace the control board as necessary. 

The gate can open, 
but fails to close. 

1. Photocell is obstructed. Remove obstruction. 
2. Check the limit switch.  Remove  the wire connection of the limit switch 
which is connected to the 9#, 10#, and 11# terminals of the control board and 
then try it again.  Replace the limit switch if the motor could run in both 
directions. 
3. Check the control board. Replace the control board if necessary. 

Summary of Contents for RK2600

Page 1: ...OPENS Website http www topenstool com RK2600 T Please read and follow all warnings precautions and instructions before installation and use Periodic checks of the opener are required to ensure safe op...

Page 2: ...Technical Specifications Features 5 Installation Overview 6 Installation of the Opener 6 Manual Operation 7 Fit the Rack 8 Install the magnets for Limit Switches 8 Connecting of Power Supply 9 Connect...

Page 3: ...factory declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation w...

Page 4: ...table for use The gate should be mounted and moved freely Check that the structure is sufficiently strong and rigid and that its dimensions and weights conform to those listed in the specifications ta...

Page 5: ...4 Parts List Extra Parts for RK2600T...

Page 6: ...t TOPENS Store Technical Specifications Features Specifications RK2600 T Power supply 110V 120V 60Hz or 220 240V 50Hz Motor voltage 120VAC or 230VAC Absorbed power 1000W Gate moving speed 20 cm s 8 in...

Page 7: ...tor Running Time MRT for multiple safety protection 90 seconds Reliable electromagnetism limit for easy adjustment Can be equipped with wide range accessories Installation Overview Installation of the...

Page 8: ...duits have to pass through the hole in the base plate 3 Pour concrete and before it starts to harden check that it is parallel to the gate leaf and perfectly level 4 The four anchor bolts must be set...

Page 9: ...oper on the gear of opener weld the second nut 4 Repeat same steps of first rack section to install the rest rack sections until proper length is reached 5 Cut away any excess of the rack Note rack le...

Page 10: ...photocell is included in the package The photocell must be installed with the gate opener for safety protection or the gate opener could not close properly 1 Contactors The A1 terminal of both contact...

Page 11: ...0 pushing the button open stop close stop open 6 Exit Wand Optional First insert the Adapter BOARD into the CONTROL BOARD and then connect the wand to the control board refers to following instruction...

Page 12: ...ected into the 15 terminal Setting of the Control Board WARNING Ensure the gate opener is Power Off when you make any adjustment of the gate opener Keep away from the gate during you set the gate open...

Page 13: ...hase additional remote controls the gate opener must be programmed to accept the new remote code If you lose one of any remote control please erase and reprogram all other remote controls to have a ne...

Page 14: ...you may program either C button or D button with TOPENS swing gate opener Wireless Keypad Programming You can follow the below steps to program wireless keypad to the opener Press the LNSW button unt...

Page 15: ...he control board as necessary Remote control does not work 1 The indicator light of remote control is not on Check the battery in your remote control Replace the battery as necessary 2 The distance yo...

Page 16: ...ire Ensure the opener is well earthed and correctly terminated Always check the Stop Reverse in case of obstruction function when performing any maintenance If this function can t be made operable rem...

Page 17: ...e do not hesitate to contact us E mail support topenstool com Kindly include your Product Model Purchasing Date Site Order and your contact information All your concerns will be replied within 24 hour...

Reviews: