11
The
BLACK
wire of the exit wand should be connected into the “#18” terminal.
The
BLUE
wire of the exit wand should be connected into the “#17” terminal.
The
RED
wire of the exit wand should be connected into the “#12” terminal.
The
GREEN
wire of the exit wand should be connected into the “#13” terminal.
The sensitivity adjustment board should be wired to the
GREEN
wire and the
YELLOW
wire of the wand. No
matter the polarity.
7. External Receiver (Optional)
The
BROWN
wire of the external receiver should be connected into the “16” terminal.
The
BLACK
wire of the external receiver should be connected into the “13” terminal.
The
RED
wire of the external receiver should be connected into the “12” terminal.
8. Wired Keypad (12VDC) (Optional)
The
RED
wire of the wired keypad should be connected into the “12” terminal.
The
BLACK
wire of the wired keypad should be connected into the “13” terminal.
The
PURPLE
wire of the wired keypad should be connected into the “16” terminal.
The
BLUE
wire of the wired keypad should be connected into the “15” terminal.
Setting of the Control Board
WARNING: Ensure the gate opener is Power Off when you make any adjustment of the gate
opener. Keep away from the gate during you set the gate opener system in case of the unexpected
gate moving. Carefully adjust the DIP switches to avoid the risk of machine damage and injury or
death. Always ask the help of professional
technician /electrician if you have any question.
1. DIP Switches
The DIP switches are used to set the running time of
the motor in midway mode, auto close time of the
gate opener and fast change the open/close direction
which is determined by the position of the gate
opener installed.
DIP Switch #1–#2: Running time of the motor in Midway Mode
This mode enables user to drive the vehicle through the gate quickly when the gate opens to certain width.
DIP Switch #1: ON
– 4 Seconds
OFF
– 0
DIP Switch #2: ON
– 2 Seconds
OFF
– 0
NOTE: The midway mode function would be disabled if both DIP switches are turned off. Factory
default setting is disabled. The midway mode could be activated by pressing button B of the remote
control when the gate is in the full closed position.
E.g. Running time of the operator in midway mode is 4+2=6 seconds.