TRL-35 Configuration
TRL-35 Operator’s Manual
2-10
• Mode
The Radio Operation mode. To set the TRL-35 into
transmit mode, choose Transmitter as the Mode. In
Simplex protocol, the TRL-35 currently supports
operation as a Transmitter, Receiver, or Repeater
.
• Link Rate
The default link rate for DBPSK is 9600 and is recommended
for most applications. The link rate is the rate at which data is
transmitted over the RF Link.
•
Output power
Select the level of power for RF transmissions ranging
from 500 mW to 32W (45 dBm)
.
10. Click on the
Serial Interface
tab.
Figure 2-11. Serial Interface Screen
Table 2-1. Modulation Type for Link Rate
For Link Rate
Use Modulation Type
4800 baud
DBPSK
9600 baud (default; recommended)
DBPSK (recommended) or DQPSK
19200 baud
DQPSK
Summary of Contents for TRL-35
Page 1: ...42 PERATORlS ANUAL 42 IGITAL 5 2ADIO ODEM ...
Page 2: ......
Page 4: ...ECO 3041 ...
Page 12: ...Preface TRL 35 Operator s Manual Notes viii ...
Page 16: ...Introduction TRL 35 Operator s Manual Notes 1 4 ...
Page 32: ...TRL 35 Configuration TRL 35 Operator s Manual Notes 2 16 ...
Page 40: ...Safety Warnings TRL 35 Operator s Manual Notes B 4 ...
Page 44: ...Warranty Terms TLR 35 Operator s Manual Notes D 2 ...
Page 45: ...Notes Notes ...
Page 46: ...Notes Notes ...