MINTER Description and Configuration
P/N 7010-0935
3-11
•
Always append to the file
on page 3-12
•
Files Creation mode
on page 3-12
•
Automatic File Rotation Mode (AFRM)
•
FN key mode
on page 3-13
•
Initial data collection dynamic mode
on page 3-14
•
Data recording auto-start
Figure 3-10. Receiver Configuration – MINTER Tab
Recording Interval parameter
This parameter specifies the message
output interval into the log file when the MINTER
FN
button (pressed
for 1–5 seconds) activates data logging. This setting is used for both
logging a single log file and logging receiver data in AFRM mode.
Values are 1–86400 seconds. The default value is one second.
Elevation Mask for Log File parameter
This parameter specifies the
minimum elevation angle for the satellites whose data will be put in
the receiver files logged when pressing
FN
. The default value is five
degrees.
File Name Prefix parameter
This parameter specifies the prefix
added to the names of receiver files created when pressing
FN
. The
prefix can be up to 20 characters long. The default value for the Name
Prefix is “log.”
Log file names have the following structure:
Net-G3A_OM_Book.book Page 11 Thursday, May 14, 2009 8:49 AM