Using Sonic Control at the Jobsite
P/N 7010-0781
6-3
3. Connect the coil cord to the Sonic Tracker (Figure 6-2).
Figure 6-2. Attach Coil Cord to Tracker
4. Bolt the Tracker to the bracket, and visually check to get the
L-Bar and Tracker plumb (Figure 6-3 on page 6-4).
5. Loop the coil cable through the “U” hangers or make one wrap of
the coil cord around the L-Bar to act as a strain relief for the
Tracker’s connector (Figure 6-3 on page 6-4).
6. Snap the temperature bail into place; an LED on the front
illuminates (Figure 6-3 on page 6-4). The Tracker is casted with
holes on each side for the bail to snap and lock into place.