![Topcon LN-100 Instruction Manual Download Page 24](http://html1.mh-extra.com/html/topcon/ln-100/ln-100_instruction-manual_1128569024.webp)
21
6. OUTLINE OF SURVEY
The instrument can perform a stakeout survey and a side shot method.
Use the controller for measurement.
The following shows the usable range of the instrument.
Do not operate the instrument out of the usable range shown below.
• Distance Measurement
The distance measurement limit of the instrument is a radial shape with a radius of 104 m from the
center of the instrument.
Moving the target at the limit of the distance measurement range may result in the target being
located outside the range within which measurement is possible.
By setting the guide light to “ON,” you can tell from a distance about the state of the instrument and
the direction to move the pole, by reference to the color of the light and the blinking pattern.
The left of the guide light is green and the right is red.
6.1
Usable Range
6.2
Functions of Guide Light
25
㼻
0m
100m
22m
10m
0.9m
5
㼻
4m
Center of the instrument
Usable range
Outside the Distance
Measurement Range
Guide light
Green Red