7-21
7 DATA COLLECTION
7.7 Setting Parameter of Data Collect [CONFIG.]
In this mode, the following settings of data collect mode are possible.
z
Setting Items
z
How to Set Items
Example Setting: DATA CONFIRM: YES
Menu
Selecting Item
Contents
F1: DIST MODE
FINE / CRS (1) /
CRS (10)
Select Fine /Coarse (1) /Coarse (10) mode in distance
measurement mode.
The unit to be displayed is as follows.
Fine mode: 1mm (0.2mm)
Coarse (1) mode: 1mm
Coarse (10) mode: 10mm
F2: HD/SD
HD/SD
Select the distance measurement mode Horizontal
distance or Slope distance.
F3: MEAS. SEQ.
N-TIMES /
SINGLE / REPEAT
Select to set measurement mode for distance
measurement.
F1: DATA CONFIRM
YES/NO
It is possible to confirm the result of measuring data
before the data is recorded.
F2: COLLECT SEQ.
[EDIT
→
MEAS] /
[MEAS
→
EDIT]
Select the procedure of data collection.
[EDIT
→
MEAS]: Measurement is carried out after
entering other data.
[MEAS
→
EDIT]: Measurement is carried out before
entering other data.
F3: NEZ AUTO.
CALC
ON/OFF
It is possible to calculate coordinate value of data collected
and store it into coordinate data file in every data collection.
Operating procedure
Operation
Display
1
Press the [F3] (CONFIG.) key from the data collect
menu 2/2.
The CONFIG menu 1/2 is shown.
[F3]
2
Press the [F4](P
↓
) key to display the CONFIG
menu 2/2.
[F4]
3
Press the [F1] (DATA CONFIRM) key.
[ ] indicates the current setting.
[F1]
4
Press the [F1] (YES) key.
[F1]
5
Press the [F4] (ENTER) key.
[F4]
DATA COLLECT 2/2
F1:SELECT A FILE
F2:PCODE INPUT
F3:CONFIG. P
↓
CONFIG. 1/2
F1:DIST MODE
F2:HD/SD
F3:MEAS. SEQ. P
↓
CONFIG. 2/2
F1:DATA CONFIRM
F2:COLLECT SEQ.
F3:NEZ AUTO. CALC P
↓
DATA CONFIRM
F1:YES
[F2:NO ]
ENTER
DATA CONFIRM
[F1:YES]
F2:NO
ENTER